Enabling better global research outcomes in soil, plant & environmental monitoring.

Tempe Cell Lab System

Complete setups to determine the water-holding characteristics of a soil sample using Tempe Cells.

– Automatic Vacuum Pump.
– Pressure Regulator.
– 5 or 10 Tempe Cell setups.
– Soil Core Sampling Kit.

Soil Sample Size 5.7cm diameter, 6cm tall
Pressure range -1 to 1 bar, depending upon setup

Please refer to the product details for more information.

There are several system options for the Tempe Cell Lab System:

LAB-5-5-4: Pressure system, (0 to +1 bar), laboratory version.

LAB-5-5-4

1. Automated Pressure/Vacuum Pump (2008F1), -1 to +1 bar (-15 to +15 psi) automation range.
– Electric Pressure Vacuum Pump, battery operated, with 2 batteries for a total of 24Ah. With both pressure (0-100 psi, max pressure setting) and vacuum (0-100 cb) gauges. Comes with two 3-foot long hoses, inline filter and battery charger. The pump is enclosed in a portable Pelican case.

2. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

3. Air Tank, Stainless Steel, 42 litre.
– Not included, available from hardware or plumbing supply stores.

4. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

5. Pressure Regulating System, Station 5 (0700G5), 0 to 1 bar precision.
– Precision low-pressure manifold, with 0-15 psi readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors.

6. Stand Hose (1425F1-1000L60), 183cm long.

7. Tempe Stand Kit (1425F1K1), including 5 Tempe Cells (1400B01M3-6).
– Stand with 2 built in manifolds, 5 ports per manifold, Luer connections.
– Tempe Cells accept 5.7cm diameter x 6cm tall sample cylinder (such as from the 0200CS Soil Core Sampler). Each cell includes a 1-bar high flow ceramic plate.

8. Soil Coring Kit in Case (0200CS).
– For the extraction of intact soil cores, this is an ‘undisturbed’ type sampler. A 5.7cm diameter core is extracted and held in a brass cylinder, suitable for use with the 1400B01M3-6 Tempe Cells. Supplied with two wedge coring tips, driving hammer, core extractor, spanner and strap wrench for replacing coring tips, six cylinder caps and five brass cylinders (6cm, two 3cm, two 1cm).
– Includes convenient carrying case.

LAB-5-A-4: Pressure System (0 to +1 bar), Portable.
LAB-5-A-4

1. Solar Panel (MEZ057)

2. External Battery Pack (MEB012)

3. Automated Pressure/Vacuum Pump (2008F1), -1 to +1 bar (-15 to +15 psi) automation range.
– Electric Pressure Vacuum Pump, battery operated, with 2 batteries for a total of 24Ah. With both pressure (0-100 psi, max pressure setting) and vacuum (0-100 cb) gauges. Comes with two 3-foot long hoses, inline filter and battery charger. The pump is enclosed in a portable Pelican case.

4. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

5. Air Tank, Stainless Steel, 42 litre.
– Not included, available from hardware or plumbing supply stores.

6. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

7. Pressure Regulating System in Case, Station A (0700G5CS), 0 to 1 bar precision.
– Precision low-pressure manifold, with 0-15 psi readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors; in Pelican case.

8. Stand Hose (1425F1-1000L60), 183cm long.

9. Tempe Stand Kit (1425F1K1), including 5 Tempe Cells (1400B01M3-6).
– Stand with 2 built in manifolds, 5 ports per manifold, Luer connections.
– Tempe Cells accept 5.7cm diameter x 6cm tall sample cylinder (such as from the 0200CS Soil Core Sampler). Each cell includes a 1-bar high flow ceramic plate.

10. Soil Coring Kit in Case (0200CS).
– For the extraction of intact soil cores, this is an ‘undisturbed’ type sampler. A 5.7cm diameter core is extracted and held in a brass cylinder, suitable for use with the 1400B01M3-6 Tempe Cells. Supplied with two wedge coring tips, driving hammer, core extractor, spanner and strap wrench for replacing coring tips, six cylinder caps and five brass cylinders (6cm, two 3cm, two 1cm).
– Includes convenient carrying case.

LAB-5-A-4: Pressure System (0 to +1 bar), bare essentials.

LAB-5-A-4essentials

1. Automated Pressure/Vacuum Pump (2008F1), -1 to +1 bar (-15 to +15 psi) automation range.
– Electric Pressure Vacuum Pump, battery operated, with 2 batteries for a total of 24Ah. With both pressure (0-100 psi, max pressure setting) and vacuum (0-100 cb) gauges. Comes with two 3-foot long hoses, inline filter and battery charger. The pump is enclosed in a portable Pelican case.

2. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

3. 4-Litre safety jar assembly (1930K3)
– Safety coated glass jar. 1/4″ outer diameter Teflon tubing, stoppers and luer connectors.

4. Stand Hose (1425F1-1000L60), 183cm long.

5. Pressure Regulating System in Case, Station A (0700G5CS), 0 to 1 bar precision.
– Precision low-pressure manifold, with 0-15 psi readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors; in Pelican case.

6. Stand Hose (1425F1-1000L60), 183cm long.

7. Tempe Stand Kit (1425F1K1), including 5 Tempe Cells (1400B01M3-6).
– Stand with 2 built in manifolds, 5 ports per manifold, Luer connections.
– Tempe Cells accept 5.7cm diameter x 6cm tall sample cylinder (such as from the 0200CS Soil Core Sampler). Each cell includes a 1-bar high flow ceramic plate.

LAB-5-56-4: Vacuum/Pressure system, (-1 to +1 bar).

LAB-5-56-4

1. Pressure Regulating System, Station 5 (0700G5), 0 to 1 bar precision.
– Precision low-pressure manifold, with 0-15 psi readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors.

2. Precision Vacuum Manifold (0725G1 or 0725G2)
– 0725G1: Vacuum manifold, with 0 to -15 psi vacuum readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors. 0.05% accuracy.
– 0725G2: Precise low-pressure vacuum control manifold. 0 to -5 psi vacuum readout gauge (graduated in 0.02 psi and 0.002 bar intervals), with control valves, tubing and connectors.

3. Automated Pressure/Vacuum Pump (2008F1), -1 to +1 bar (-15 to +15 psi) automation range.
– Electric Pressure Vacuum Pump, battery operated, with 2 batteries for a total of 24Ah. With both pressure (0-100 psi, max pressure setting) and vacuum (0-100 cb) gauges. Comes with two 3-foot long hoses, inline filter and battery charger. The pump is enclosed in a portable Pelican case.

4. Air Tank, Stainless Steel, 42 litre.
– Not included, available from hardware or plumbing supply stores.

5. Tempe Stand Kit (1425F1K1), including 5 Tempe Cells (1400B01M3-6).
– Stand with 2 built in manifolds, 5 ports per manifold, Luer connections.
– Tempe Cells accept 5.7cm diameter x 6cm tall sample cylinder (such as from the 0200CS Soil Core Sampler). Each cell includes a 1-bar high flow ceramic plate.

6. 4-Litre safety jar assembly (1930K3)
– Safety coated glass jar. 1/4″ outer diameter Teflon tubing, stoppers and luer connectors.

7. 1-Litre safety jar assembly (1930K2)
– Safety coated glass jar. 1/4″ outer diameter Teflon tubing, stoppers and luer connectors.

8. Soil Coring Kit in Case (0200CS).
– For the extraction of intact soil cores, this is an ‘undisturbed’ type sampler. A 5.7cm diameter core is extracted and held in a brass cylinder, suitable for use with the 1400B01M3-6 Tempe Cells. Supplied with two wedge coring tips, driving hammer, core extractor, spanner and strap wrench for replacing coring tips, six cylinder caps and five brass cylinders (6cm, two 3cm, two 1cm).
– Includes convenient carrying case.

LAB-5-6-4: Vacuum System (0 to -1 bar)

LAB-5-6-4

1. Automated Pressure/Vacuum Pump (2008F1), -1 to +1 bar (-15 to +15 psi) automation range.
– Electric Pressure Vacuum Pump, battery operated, with 2 batteries for a total of 24Ah. With both pressure (0-100 psi, max pressure setting) and vacuum (0-100 cb) gauges. Comes with two 3-foot long hoses, inline filter and battery charger. The pump is enclosed in a portable Pelican case.

2. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

3. Air Tank, Stainless Steel, 42 litre.
– Not included, available from hardware or plumbing supply stores.

4. Extension Hose (0775L60), 183cm long.
– 1/2″ outer diameter, 1/4″ inner diameter pressure tubing, with swivel fittings.

5. Pressure Regulating System, Station 6 (0725G1), 0 to -1 bar, Precision.
– Vacuum manifold, with 0 to -15 psi vacuum readout gauge (graduated in 0.1 psi and 0.005 bar intervals), control valves, tubing and connectors. 0.05% accuracy.

6. Stand Hose (1425F1-1000L60), 183cm long.

7. 4-Litre safety jar assembly (1930K3)
– Safety coated glass jar. 1/4″ outer diameter Teflon tubing, stoppers and luer connectors.

8. Stand Hose (1425F1-1000L60), 183cm long.

9. 1-Litre safety jar assembly (1930K2)
– Safety coated glass jar. 1/4″ outer diameter Teflon tubing, stoppers and luer connectors.

10. Stand Hose (1425F1-1000L60), 183cm long.

11. Tempe Stand Kit (1425F1K1), including 5 Tempe Cells (1400B01M3-6). (Two kits, total of 10 Tempe Cells)
– Stand with 2 built in manifolds, 5 ports per manifold, Luer connections.
– Tempe Cells accept 5.7cm diameter x 6cm tall sample cylinder (such as from the 0200CS Soil Core Sampler). Each cell includes a 1-bar high flow ceramic plate.

12. Stand Hose (1425F1-1000L60), 183cm long.